Wintronics Inc - Home Pages

WINTRONICS, INC.
50 Division Avenue
PO Box 337

Millington NJ 07946

Toll Free (800) 247-7976
Tel. (908) 647-0144
Fax (908) 647-8379

email: win@wintron.com

Wintronics Inc

Selection Guide: KT15-Series IIP- Infrared Radiation Pyrometer

Click here to download complete KT15-Series IIP technical specifications, including temperature ranges and resolution tables.

Selection Guide: Infrared Radiation Pyrometer KT15-IIP-Series
Model Spectral Response/um tmin..tmax/°C Typical Application
KT15.01-IIP 2.00...2.70 250...2500 metals, metal oxides, ceramics and glass volume
KT15.02-IIP 2.00...4.50 150...2500 metals, metal oxides, glass volume (low temperatures)
KT15.22-IIP 5.70±0.10 40...400 thin film plastics (special cases)
KT15.23-IIP 6.80±0.15 0...400 thin film plastics, e.g. PE, PP, PS
KT15.24-IIP 7.93±0.15 0...400 tin film plastics, e.g. PET, Acrylic, PC, PU, FEP, acetate
KT15.25-IIP 8.05±0.15 0...400 thin film plastics, e.g. PTFE, PVC, polyimide, acrylic, PC, PU, FEP, acetate
KT15.41-IIP 3.90±0.10 250...2500 glass volume, measurements through hot gases and flame
KT15.42-IIP 4.90...5.50 100...2500 glass and quartz surface and through hot gases and flame
KT15.43-IIP 7.50...8.20 0...1400 glass and quartz, surface thin ceramics
KT15.61-IIP 4.26±0.13 400...2500 hot gases and flame (CO2-band)
KT15.62-IIP 4.50±0.10 400...2500 hot gases and flame (CO2-and CO-band)
KT15.63-IIP 4.66±0.10 400...2500 hot gases and flame (CO-band)
KT15.69-IIP x...y 0...1700 hot gases in incinerators and fossil fuel fired utility boilers
KT15.81-IIP
KT15.82-IIP
KT15.83-IIP
8...10
8...14
8...20
0...1000
-30...1000
0…500
paper, textiles, rubber, wood, ceramics, thicker plastics (>1 mm)enamel or coated surfaces, asphalt, building materialselectronic components, food, liquids and meteorological, biological, agricultural studies
KT15.85-IIP 9.6-11.5 -25...200 Meteorology, long distance water, ice & cloud temperature measurement
KT15.99-IIP x…y -50…3000 Various custom spectral bands for customer specific applications
KT15-IIP-Series General Specifications
Temperature range

Depends on model, minimum and maximum measuring temperature. (See table above)

Temperature resolution (NET)*

Depends on model, detector size, measuring temperature and response time typical value ±0.1°C ±0.2°F)

Calibration accuracy

±0.5°C plus 0.7% of the difference between target temperature and housing temperature

Long-term stability

Better than 0.01% of the absolute measured temperature in Kelvin/month

Lenses*

Several far-focus and close-focus lenses are available. See literature Field of view diagrams

Field of view*

Depends on model, detector and lens type. For close focus lenses: from 0.8 mm diameter at <20 mm distance; for far-focus lenses, typically 20 to 30 mm diameter at distances >1000 mm

Aiming accessories*

Optional integrated laser pointer or focus laser. Several external optical and mechanical options are available.
See literature Options and Accessories

Emissivity setting

Manually adjustable from 0.10 to 1.00, or programmable in 0.001 increments

Response time

Selectable: 50 ms, 100 ms, 300 ms, 1 s, 3 s or 10 s for +90.
Optionally 5mS to 600S

Analog output

4 scalable output signals: linear voltage or current, 0-1(10)V or 0(4)-20 mA. Integrated peak/valley picking w/ programmable decay. Output can be temperature or relative radiance

Serial Interface (Option)

RS-232 interface, bi-directional, baud rate 9600 to 115,000 bps, for free programming and data transfer

Power requirements

24 VAC ±10%, 48 to 400 Hz, or 22 to 30 VDC, max. 130 mA with 24 VDC. Optional 9-36VDC, 12-24VAC

Permissible ambient temperature

-20 to 60°C (-4 to 140°F) or up to 315°C (600°F) with WK200L cooling jacket

Storage temperature

20°C to 70°C (-4 to 158°F)

Housing protection/weight

IP 65 (DIN 4005) NEMA 4 equivalent, approx. 0.55 kg. 1.2 lbs)

Wintronics Inc., exclusive US agent for Heitronics Infrared Radiation Pyrometers

Copyright © 2004 Wintronics Inc.

Home | Infrared Thermometers | About Heitronics | Products | Services |
IR Applications | Guide to Non-Contact Temp. Measurement | Tech Notes | Downloads